Roadway Standard Drawings (400-600 series)

Print
Press Enter to show all options, press Tab go to next option
           
Roadway Standard Drawings (400-600 series)
No.  Drawings Revised
 All Roadway Standard Drawings March 2018
400  Standard 4' Diameter Brick masonry storm Sewer Manhole Aug. 2014 
401  Standard 5' Diameter Brick masonry storm Sewer Manhole Aug. 2014 
402  Standard 4'-6" Brick Masonry Curb Inlet Dec 2009
403  Standard 6' Brick Masonry Curb Inlet Dec 2009
404  Standard Offset Curb Inlet June 2008
405  Standard 20" x 26" Grate and Frame (Heavyweight) Sept 2008
406  Standard 24" x 24" Grate and Frame (Lightweight) Sept 2008
407  Standard 24" x 24" Grate and Frame (Heavyweight) Sept 2008
408  Standard 5" x 12" Steel Flume June 1999
409  Standard Brick Masonry Drop Inlet for 20" x 26" Grate Dec 2007
410  Standard Brick Masonry Drop Inlet for 24" x 24" Grate Dec 2007
411  Standard Inlet Ring and Cover March 2008
412  Standard Precast Concrete Curb Inlet Top Sept 2008
412-A  Standard Reinforced Nose Plate for Curb Inlet Top n/a
413  Standard Manhole Ring and Cover June 2013 
414  Standard Plastic Step for Brick Masonry Structures Mar 2001
415  Standard Concrete Encasement for Manhole and Valve Castings in Pavement June 2004
416  Typical Walk and Driveway Section for Curb and Gutter Streets March 2011
416-A  Typical Commercial Driveway Section Dec 2012 
416-B  Street Type Commercial Driveway Dec 2012
417  Standard Concrete Steps and Buttress Walls n/a
418  Standard Concrete Curb Ramp March 2012 
418-A   Sidewalk Standard for Use with Typical Street Sections June 2013
419  Standard Pipe Collar n/a
420  Standard Conversion Top Curb and Drop Inlets to Junction Box Sept 2011 
420-A  Standard Conversion or Curb Inlet to Junction Box March 2001
420-B  Inlet Conversion for Drive Entrance Storm Sewer Pipe Parallel to Curb n/a
420-C  Inlet Conversion for Drive Entrance Storm Sewer Pipe Perpendicular  to Curb n/a
421  Standard Dead End Street Erosion Control Device Sept 2010
422  Standard Pipe Outlet Erosion Control Device March 1997
423  Standard Pavement Repair for Pipe/Utility Placed Under Existing Pavement (Roadway) March 2018 
423-A  Standard Pavement Repair for Pipe/Utility Placed Under Existing Pavement (Asphalt Drives) March 2018
424  Standard 4' x 4' Brick Masonry Yard Inlet Dec 2007
425  Standard 4' x 4' Precast Concrete Yard Inlet Cover with Ring and Cover Dec 2007
426  Standard Subdrain Fabric Installation Aug 2002
427  Standard Brick Masonry Curb Inlet for Medians Aug 2002
428  Standard Precast Concrete Curb Inlet Top to be Used with COG STD #427 n/a
429  Standard Brick masonry Pipe Plug n/a
430  Standard Silt Fence Detail March 2009
431  Standard Stormwater Inlet Protection Measures Dec 2006
432  Standard Temporary Stone Ditch Check Sept 2010
433  Standard Temporary Silt Check Dam, Type A Sept 2010
434  Standard 24" x 36" Grate and Frame (Heavyweight) Sept 2008
435  Standard Brick Masonry Drop Inlet for 24" x 36" Grate Dec 2007
436  Temporary Construction Entrance Detail (City Requirements) March 2009
436-A  Temporary Construction Entrance Detail (State Requirements) March 2009
436-B  Temporary Construction Entrance Detail (Residential Sites) March 2009
437  Standard Pipe Underdrain n/a
438  Standard 6' x 6' Brick Masonry Yard Inlet Dec 2007
439  Standard 6' x 6' PreCast Concrete Yard Inlet Cover with Ring and Cover Dec 2007
440  Temporary Earth Berm n/a
441  Standard 5' x 5' Brick Masonry Yard Inlet Dec 2007
442  Standard 5' x 5' PreCast Concrete Yard Inlet Cover with Ring and Cover Dec 2007
443  Partially Installed Storm Sewer Protection June 2005
443-A  Inlet Protection for F.E.S June 2005
444  Typical Under Drain Detail for Grass Median June 2007
446  Safety Fence for Pedestrians with Handrail Option March 2015
446-A  Safety Fence for Pedestrians with Handrail Options (for use in areas with line of sight issues) March 2015
447  Standard Concrete Gravity Retaining Wall March 2012
448  Standard Tree Protection Detail March 2010
449  Storm Drainage Pipe Reinforced Concrete Sept 2008
450  Sediment Control Log Installation for Existing Curb Inlets Next to Traffic March 2009
451  Bus Stop Detail - with Shelter Dec 2011
452  Bus Stop Detail - without Shelter Dec 2011
453  Rock Pipe Inlet Protection June 2009
454  Water Bar Detail (Right-of-Way Diversion) June 2009
455  Connection for HDPE Pipe to RC Flared End Section March 2010
456  Soil Tight Connection for HDPE Pipe to Drainage Structures March 2010
457  Wattle with Polyacrylamide (PAM) Dec 2010
458  Water Valve and Extension in Roadway March 2015
459       Greenway Trail - Asphalt June 2016
460  Greenway Trail - Concrete June 2016 
500  Standard 6" x 12" Concrete Parking Curb n/a
501  Standard Concrete Curb and Gutter March 2001
502  Standard Dead End Street Turn Around Area March 2018 
502-A  Turn Around Area For Dead End Street (Alternate) March 2018
503  Standard Cul-De-Sac Jan 1991
504  Standard Cold Milling Section (Curb Reveal) n/a
600  Typical 24' Face to Face Street Section March 2018 
601  Typical 26' Face to Face Street Section March 2018 
603  Typical 30' Face to Face Street Section March 2018
605  Typical 36' Face to Face Street Section March 2018 
606  Typical 40' Face to Face Street Section March 2018 
608  Typical 48" Face to Face Street Section March 2018 
609  Typical Non-Curb and Gutter Subdivision Street March 2018
610  Typical Widening Sections 30' to 64' Face to Face March 2018 
610A   Street Widening Sections Curb and Gutter One Side Only March 2018 
611  Typical Residential Street Section Ribbon Pavement with Sidewalk March 2018

Free viewers are required for some of the attached documents.
They can be downloaded by clicking on the icons below.

Acrobat Reader Flash Player QuickTime Windows Media Player Microsoft Silverlight Word Viewer Excel Viewer PowerPoint Viewer